Page 138 - Regent - Electrical Product Guide
P. 138
SWITCHGEAR, DISTRIBUTION & CONTROL
Switch Disconnectors
Glasgow Fuse-Switch-Disconnectors & Switch-Disconnectors
All units are supplied with fuselinks or switchlinks fitted. Glasgow fuse switch disconnectors and switch disconnectors meet the constructional requirements for isolation of and are type tested to BS EN 60947-3. Five frame sizes are available to provide a range from 63A to 800A, with utilisation category AC22A and AC23A Ue 415V ratings. All units have retractable operating handles which drive overcentre mechanisms incorporating powerful operating springs. Flag “on-off” indication is provided and terminal cover shields prevent contact with live metal. Surface-mounting enclosures comprise heavy gauge steel body
plates incorporating cast iron frame members and are rustprotected, with a light grey paint finish (RAL7004). Front access doors, which are detachable, are fitted with dust-excluding gaskets and are interlocked to prevent opening when the switch is ‘on’.
Glasgow Fuse-Switch-Disconnector
63GNL
Nominal Unit
63 125
100 125
160 (Use 200A - Switch-Disconnector)
200 315
63MLK
100MLK
22 30
22 30
• Neutral makes first and breaks last.
63
100
160
200
315
400
500
630
800
63SB4
100SD5
160SF6
200SF6
315SF7
400SF8
500SH9
630SH9
800SH10
SB3 & SB4
SB3, SB4, SO & SD5
SF3 & SF6
SF3 & SF6
SF3 & SF7
SF3 & SF8
SH8 & SH9
-
SH8 & SH10
63MLK 22 30
100MLK 22 30
200MLK 90 125
200MLK 90 125
400MLK 110 150
400MLK 110 150
630MLK 225 300
630MLK 225 300
800MLK 300 400
Copper Switch Links Fitted
Motor Ratings AC23A Ue 415V
kW
HP
• Units are fitted with HRC Fuselinks of maximum rating but will accept fuselinks of a lower rating.
• SPSN and TPSN indicate switched neutral.
Part No.
61GNC
Poles
Nominal Unit Rating, Ie (A)
Eaton 415V Fuse(s) Fitted
Suitable Fuselinks
Copper Switch Links Fitted
Motor Ratings AC23A Ue 415V
kW
HP
63GNC
SPSN
TPN
64GC
TPSN
101GNC
SPSN
103GNC
TPN
104GC
TPSN
151GNC
SPSN
153GNC
TPN
154GC
TPSN
201GNC
SPSN
203GNC
303GNC
TPN
204GC
TPSN
TPN
304GC
TPSN
403GNC
TPN
404GC
TPSN
503GNC
TPN
603GNC
TPN
604GC
TPSN
803GNC
TPN
804GC
TPSN
103GNL
-
138
Together we generate value
Part No.
203GNL
Nominal Rating, Ie AC21 (A)
-
403GNL
-
603GNL
803GNL
Part No.
-
15AXD2
Poles
SPSN
DP
Utilisation Category at Ue 415V to BS EN 60947-3
AC22A (A)
AC23A (A)
250V DC Rating to BS5419 DC23 (A)
20 11 201)
32 22 32 -
- --
200MLK
90 125
315 (Use 400A - - -- Switch-Disconnector)
400 630
500 (Use 630A - Switch-Disconnector)
630 1000
800 1000
400MLK
-
400MLK
800MLK
110
-
225
300
150
-
300
400
* If DP fuse-switch-disconnectors are required, use SPSN and replace the supplied switch link with a compatible fuselink. Stud size: 63/100A = tunnel terminal, 160/200A = M10, 300/400 = M14, 500/800A = see page 148, “copper terminal plate”
Exel 2 switch disconnectors and switch-disconnector fuses meet the constructional requirements for isolation of and are type tested to BS EN 60947-3. Switches are of the quick make and break type, suitable for use on AC or DC. Units have removable moving contact assemblies to facilitate wiring.
Exel 2 surface-mounting enclosures are fabricated from rust-protected sheet steel with a light grey paint finish. Removable blank top and bottom end plates (except for 20 and 32A top end plates which incorporate knockouts) and gasket doors give IP41 protection. Chromium-plated front operated handles, with “ON (I) OFF (O)” indication, and internal fixing enabling units to be mounted closely side by side. Interiors comprise porcelain bases fitted with non-ferrous conducting components.
Exel 2 Switch-Disconnectors & Switch-Disconnector Fuses
Blank Endplate
15AXTN2
TPN
-
SPSN
30AXD2
DP
30AXTN2
TPN
-
SPSN
63 - 63 39
EP 842
EP 539
60AXD2
DP
60AXTN2
100 - 100 - 52
125 52 - -
SPSN indicates switched neutral. 1) 20A units are DC22.
100AXD2
TPN
-
SPSN
DP
100AXTN2
TPN
125AXTN2
TPN