Page 225 - Regent - Electrical Product Guide
P. 225

  FIRE & SECURITY
  Fire Alarm Systems
   CFP Conventional Systems
LPCB certified to the latest revisions of EN54 parts 2 and 4, the new-look super-enhanced CFP conventional fire panel offers an array of user and installer-friendly features at a very competitive price.
Each of the 2, 4, or 8 zone panels available feature four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry.
• LPCB certified to the latest versions of EN54 Parts 2 and 4.
• 2, 4 or 8 zone circuits (dependent on model).
• Four conventional sounder circuits.
• Integral 1.5A EN54-4/A2 compliant switch mode PSU.
• Wide range of engineering functions including zone test, coincidence*, zone delay and non-latching zones*.
• Two on-board relays (Fire and Fault).
• Two open-collector outputs (Remote & Reset).
• ‘Class change’ and alert inputs.
• Installer-friendly design accommodates easy first fix and straightforward maintenance.
• Attractive flush or surface mountable plastic lid and enclosure - no bezel required.
• Low 25mA quiescent current.
• End of line units included (one per zone).
• Ancillary system expansion connections provided for up to eight two-wire repeaters (one CFP761 network driver card required per system) and optional CFP relay boards.
2 Zone CFP Conventional Control Panel 4 Zone CFP Conventional Control Panel 8 Zone CFP Conventional Control Panel 3.4AH Batteries (x2 Required)
S65 Optical Smoke Detector S65 Ionisation Smoke Detector S65 Rate of Rise 57’c A1R Heat Detector
S65 Static 90’c Heat Detector S65 Diode Base
Roshni Sounder
Solista Sounder / Beacon (VID)
           Part No.
  Panels
Description
Part No.
EN54-23 Visual Alarm Devices (VAD’s)
Description
      P-3032
AV-1040
Wall Sounder/Beacon - Red Body, White Flash
 P-3033
  SBE-2003
  P-3034
Wall Beacon - Red Body, White Flash
  BAT-3002
  SBE-2002
Ceiling Beacon - White Body, White Flash
  Detectors
  SD-1000
  Call Points
  SD-1001
   SD-1002
CP-1000
Universal Call Point
   CP-1001
Call Point Glass (pack of 10)
  CP-1003
Call Point Protective Cover
  SD-1005
  Bells
  SD-1006
   Sounders / Beacons
BEL-1015
6 Inch Red Bell
     SDR-3001
  AV-1009
          AlarmSense® Bi-Wire System
The new Pulse2 AlarmSense® range consists
of a series of conventional, 2, 4 & 8 zone fire alarm control panels designed and approved in accordance with European standards BS EN54- 2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment.
• Fully certified to BS EN54-2 and BS EN54-4.
• Allows systems to be installed in accordance
with BS5838: Part 6.
• 2 wire systems, reduces installation cabling.
• 2-wire repeaters and ancillary boards via serial bus.
• Fully programmable using simple menu options.
• Adjustable sounder delay time.
• Sounder configuration options.
• Zonal sounder delay for detectors only.
• Zonal sounder delay for call points only.
• Coincidence output via ancillary board.
• Short circuit fire selectable by zone.
• Non latching selection by zone.
• Silent zones (common sounder outputs).
• Zone input delay for sprinkler system connection.
• AlarmSense® local alarm feature supported.
• Simple, single board construction.
• Installer friendly.
• Compatible with all AlarmSense® devices.
• Two conventional monitored sounder outputs.
• 3 Amp power supply.
2 Zone Pulse Control Panel 4 Zone Pulse Control Panel 8 Zone Pulse Control Panel Relay Module (1A 30v) 7.0AH Batteries (x 2 Required)
Sounder Base
Sounder / Beacon Base (VID) Open Area Sounder
Open Area Sounder / Beacon (VID)
Optical Smoke Detector + Sounder + Beacon (VID)
Heat Detector A1 + Sounder + Beacon (VID)
Optical Smoke Detector + Sounder Heat Detector A1 + Sounder Optical Smoke Detector
Heat Detector A1 Detector Base
Call Point
Call Point Protective Cover
             Part No.
  Panels
 AS-3000
SD-6013
Description
  SD-6000
 AS-3001
 SD-6002
  AS-3002
    SD-6004
  BAT-3003
  SD-6005
  Sounders / Beacons
  SD-6007
  SD-6014
  SD-6009
  SD-6015
Part No.
Description
  Detectors
   SD-6011
  SD-6018
  Call Points
  SD-6019
  SD-6022
    AD-2070
          Together we generate value
225
   